Ⅰ
Brief instruction:
One-component
environmental-friendly adhesive,work
in room temperature. Strong adhesive ability, good
flexibility and excellent electronic properties after
curing.
Ⅱ
Product data |
|
Items |
Testing Standard |
2506 |
Appearance |
Visual |
Yellow clean
liquid |
Viscosity |
25℃
mPa.·s |
100±50 |
Solid content |
% |
50 |
Gel time |
25℃,
50%RH, h |
1~2 |
Curing schedule |
25℃,
50%RH, h |
24~48 |
Pot life
|
25℃,
50%RH, min |
20 |
NCO |
% |
4±0.5 |
Density |
25℃,
g/ml |
1.15±0.05 |
Storage period |
<25℃,
sealed |
6 months |
Ⅲ
Storage and transportation:
1, the product belongs
to non-dangerous material. Storage and transportation follow
regular chemicals regulation. The storage period of time see
packing barrel.
2, store and seal the
goods with the temperature bellow 25℃
after use
3, 2506 is one-content
glue, daub or pile it on the objects and fold them after several
minutes.
Ⅳ
Packing
Packed in 4Kg barrel or
8Kg barrel.
MATERIAL SAFTY DATA
Product:
2506
Specialty:
Main content: MDI
Characteristics:
Appearance: yellow clean liquid
Smell: a bit irritant
Specific gravity
(water-1): 1.15±0.05
Harm:
Acute toxicity: none
Injurant in
decompounding: CO, CO2
Health precaution:
Using this product must
obey relative health rules.
Precaution:
Protective
garments: needed
Glove: needed
Goggles: needed
Mask: not recommended
Work
place: ventilate constantly
Operator should avoid
breathing vapors
Use cotton or sawdust to
absorb material then put it into plastic bag.
Emergency treatment:
If eyes contact epoxy,
hardener or mixture, flush thoroughly with clean water for 15
minutes, then seek medical treatment.
Wipe the material from
skin, and then wash exposed areas immediately using warm water
and soap. If skin is seriously imitated medical treatment is
needed.
Avoid breathing vapors,
which can cause respiratory damage.
Any unusual phenomena's
appear, seek medical treatment.
Fire control:
Using CO2 or