At room temperature hardening plastic electronic confidentiality \ modules confidentiality plastic \ plastic chips confidentiality 904-1A/-1B

I. Introduction:
At room temperature hardening plastic electronic confidentiality \ modules confidentiality plastic \ 904-1A/-1B plastic chips confidentiality is a two-group-type potting material at room temperature hardening, which become dense in the cured solid structure, high hardness, heat good performance, it is extremely difficult to demolish, to protect, waterproof, the role of secrecy.

Second, conventional performance:

 Test items

Testing methods or conditions

904-1A

904-1B

Appearance

Visual

Black viscous liquid

Colorless transparent liquid

Density

25℃ g/cm3

1.5~1.6

1.00~1.10

Viscosity

25℃ mpa·s

3000~5000

150~300

Retention period

Room ventilation

Six months

Six months


Third, the use of technology:

Item

Unit or the conditions of

904-1A/904-1B

Mixing ratio

 Weight ratio

100:20

Can use the time

25℃35ghrs

0.5

Curing conditions

℃/hrs

25/24 or 60 / 3

Fourth, use: apply to sensors, hybrid circuit modules, small electronic components such as confidentiality.
Fifth, after the curing characteristics:

 Hardness

Shore-D

80

Volume resistivity
 

25℃Ω·cm

1.0×1014

 Dielectric Strength

25℃kV/mm

15

 Impact strength

Kg/cm2

7

 Permittivity

25℃1MHZ

4.0±0.05

Dielectric Loss Tangent

25℃1MHZ

0.02

6, storage, transportation and Cautions:
1. Such products of non-dangerous goods, as a general storage and transportation of chemicals, product packaging, see barrels of storage period.
2. Please see the product model, and then pigeon-holing; accurate weighing, please give full uniform mixing.
3. By encapsulating the device was 100 ℃ / 1 ~ 1.5hrs drying to remove water, cooling to 30 ~ 40 ℃.
4. Encapsulation when the attention should not be dipping fast speed in order to ensure uniform impregnation.
7, packing specifications: Packaging for metal containers 5KG or 25KG.
 

Note: The above performance data for the product in 70% humidity, the temperature at 25 ℃ typical testing data for customers reference and can not guarantee that in a particular environment can be achieved when all the data. When your customers use to the measured data.

back